Analytical parameters
analytical_parameters
This table documents the reference materials and standards used during the analysis of samples
Analytical parameters identifier
analytical_parameters_id
This field contains the unique identifier for the set of analytical parameters associated with a specific analysis.
Type | Required | Table |
---|---|---|
identifier | yes | organic_measures , mineral_measures , radiocarbon_measures , amino_acid_measures , analytical_parameters |
Standard
standard
This field records the name or type of standard used during the analytical run. The standard refers to a reference material or known benchmark used to calibrate the equipment or validate the accuracy of the measurements taken.
Type | Required | Table |
---|---|---|
string | no | analytical_parameters |
Known value
known_value
This field contains the expected or known value of the standard being used. This value serves as the reference against which the measured results are compared to assess the accuracy and reliability of the analytical process.
Type | Required | Table |
---|---|---|
decimal | no | analytical_parameters |
Measured proxy
measured_proxy
This field specifies the element or isotope proxy that was measured during the analytical run. Examples include isotopic measurements such as δ13C, δ34S, δ18O, etc. This field indicates the specific proxy being analyzed.
Type | Required | Table |
---|---|---|
string | no | analytical_parameters |
Allowed Values:
δ13C
δ15N
δ34S
δ13C carbonate
δ18O carbonate
δ18O phosphate
δ18O total
87Sr/86Sr
δ88Sr
143Nd/144Nd
Measured value
measured_value
This field records the actual value obtained for the measured proxy during the analytical run. It represents the experimental result and is compared against the known value of the standard to evaluate the success of the measurement.
Type | Required | Table |
---|---|---|
decimal | no | analytical_parameters |
Measured uncertainty
measured_uncertainty
This field represents the uncertainty associated with the measured value. Expressed to one decimal point, it indicates the range or degree of variability in the measurement, reflecting how confident the researcher is in the accuracy of the measured result.
Type | Required | Table |
---|---|---|
decimal | no | analytical_parameters |
Measured uncertainty type
measured_uncertainty_type
This field specifies the type of statistical uncertainty associated with the measured value. Accepted values are “sd”, “2sd”, “se” or “2se”. This clarifies the basis of the uncertainty measurement, helping to interpret the level of confidence and precision in the reported value.
Type | Required | Validations | Table |
---|---|---|---|
string | no | Lowercase: yes | analytical_parameters |
Allowed Values:
sd
2sd
se
2se